spectraval 1511 is a modern spectroradiometer for the VIS wavelength range, which can be used in stand alone mode or with a PC or laptop. It is equipped with a touchpad display and a SD card slot for in field measurements. The available interfaces for operation with the PC software JETI LiVal are USB and Bluetooth.
Highlights
- Fast measurement of spectral Radiance
- Radiometric software JETI Lival included in delivery
- Marking of the measuring area by a red circle
- Touchpad display with intuitive operation
- Piezo-electric driven shutter for dark signal compensation
- USB powered or battery powered
- Data storage on SD card
- Suited for HDR (luminance values up to 140 000 cd/m² can be measured)
- Implementation into customer specific applications possible using:
- Radiometric DLLs (Windows applications)
- Serial commands (SCPI -like syntax for Windows and Linux applications)
Comparison of spectroradiometers (JETI & X-Rite vs QD OLED | WRGB OLED | QLED | LCD | Laser Projektor)
Display calibration compendium with Jason Dustal, Murideo Inc. (Gear of an expert display calibrator)
spectraval 1511 is also available in the following special versions:
Specifications
Optical parameters
|
380 … 780 nm (350 … 1000 nm NIR version) |
|
4.5 nm (2 nm HiRes version) |
|
Luminance 0.2 … 140 000 cd/m² |
Measuring quantities
- Luminance, Radiance
- xy and u' v' coordinates
- Dominant wavelength, Color purity
- Correlated Color Temperature (CCT)
- CRI, CQS, TM-30
- Circadian metrics, PAR
Dimensions
Accessories
To open or to close, please click the desired underlined category.
Diffusors
Standard diffusor (ACC 032)
The pure spectraval 15x1 measures in spectral Radiance mode. It is possible to convert it into a spectral Irradiance meter by attaching a diffusor.
90° diffusor (ACC 032/90°)
The standard diffusor of the device acts in line to the device. If the Illuminance at a low height above a surface needs to be measured, then the 90° diffusor can be applied. It is also available with attenuation filters to extend the Illuminance measuring range (ACC 032 ODx.x).
90° remote diffusor (ACC 035-length)
If the measurement needs to be done under limited space conditions and the in axis fiber coupled diffusor is not suited, then the 90° fiber coupled diffusor can be applied. Different fiber lengths are available.
In axis remote diffusor (ACC 034-length)
If the measurement needs to be done in locations with limited space conditions then the remote diffusor can be used. It is a diffusor which is coupled to the spectraval device by an optical fiber bundle. The measurement is done in axis to the fiber bundle. Different fiber lengths are available.
Dome diffusor
The dome diffusor is equipped with a glass dom (silica for specbos 1211-UV-2) and it is IP67 tested. It can be mounted on roofs or outdoor walls and allows a detection of the optical sky radiation. The standard length of the fiberoptic bundle is 3 m, so also longer distances between the measuring location and the indoor position of the measuring device can be spanned.
Filters
Neutral density filter (ACC 033 OD1.0)
spectraval 15x1 can measure up to 100 000 cd/m² (typical white LED spectrum). An additional neutral density filter allows to shift the measuring range towards 10 times higher Luminance levels.
Dolby/realD filter cap pairs
The calibration of 3D projectors needs to be done through the right and left eye glasses. spectraval 15x1 can be equipped with caps containing the filters of Dolby (ACC 053) and realD (ACC 052) projection. The usage of these filter pairs allows a precise measurement of 3D projections.
Flicker meter
ACC Flicker
With the JETI flicker meter the light fluctuations of lamps, luminaires, monitors and projectors can be measured. The accessory can be easily attached to spectraval 1501 / spectraval 1511.
Imaging optics
Imaging optics for small spot sizes
specbos 1211-2 and spectraval 15x1 in its standard configuration can measure in Luminance mode only with diameters of 4 mm and more. Applications as the measurement of small segments of displays or small sized OLEDs may need smaller diameters. Therefore, JETI offers three imaging optics to reduce the measuring diameter.
Special imaging optics
Special imaging optics for spectraval 15x1
In some applications it is necessary to create a specified measuring diameter in a specified distance. This can be realized with customer specific optics.
Beam shaping optics
It is not necessary to adjust the optics of spectraval 1511 in Radiance mode, the measuring spot is sharp at any distance and the viewing angle is always 1.8°. If a specific measuring spot diameter is required, this can be set by selecting the appropriate measuring distance. In some cases this is not possible due to space limitations, e.g. in production measurements or in special set ups. Therefore, different beam shaping optics are available.
Miscellaneous
Straylight protection tube (ACC 046)
The straylight protection tube prevents the influence of surrounding light on Radiance measurements. It is mainly used for display measurements. The fixed length of the tube is 16 cm.
Applications
LED measurement
Light effects
- Measurement in architecture and architecture models
- Circadian metrics
Display and projection measurement
Miscellaneous
- Application of different color matching functions
- Long term measurements of daylight and in green houses
- General transmission/Reflexion measurements
Technical notes
Devices
Firm- and software
Communication
Downloads
Datasheets
Documentation
SDK
External software
External software
Program | Manufacturer | Software* | Driver | Firmware spectraval 1511 | SDK (DLL) |
External software packages | |||||
CalMAN | Portrait Displays | 5.9.0 | 2.12.28 | 1.0.4 | 4.4.0 |
LightSpace | Light Illusion | 7.1.7 | 2.12.28 | 1.0.4 | 4.4.0 |
ChromaPure | DisplayCalibrations | 3.0.8 | 2.12.28 | 1.0.0 | 4.4.0 |
ColourSpace | Light Illusion | 2.12.28 | 1.0.4 | 4.4.0 | |
Hardware related software | |||||
Calibrator | TVLogic | 1.7.1R1 | 1.0.4 | 4.0.18 | |
ColorNavigator | EIZO | 6.4.17.101 | 1.0.4 |
* tested version