specbos 1211-UV-2
Broadband Spectroradiometer 230 - 1000 nm
specbos 1211-UV-2 extends the original wavelength range of the device in the UV range down to 230 nm, both in Radiance (standard configuration) and Irradiance (diffusor required) mode as well. All other parameters as sensitivity, viewing angle in Radiance mode (1.8°) and optical resolution remain the same as of the standard device.
This extension makes specbos 1211-UV-2 suitable for hazard measurements according to the IES 62471 standard. Other applications are the measurement of UV exposure apparatus, suntanning banks etc.
Highlights
- Wavelength range from 230 - 1000 nm
- Measurement in Radiance (basic configuration) and Irradiance (diffusor required) mode
- Radiometric software JETI LiVal included
- Start of measurement with external trigger signal
- Highly sensitive
- Internal target spot laser
- Mechanical shutter for dark signal compensation
- Automatic measurement in selectable time intervals
- USB powered – mobile
- Start of measurement with external trigger
Specifications
Optical parameters
|
230 - 1000 nm |
|
4.5 nm |
|
Luminance 0.2 … 100 000 cd/m² |
Illuminance 1 … 1 500 000 lx |
Measuring quantities
- Luminance, Radiance
- xy and u' v' coordinates
- Dominant wavelength, Color purity
- Correlated Color Temperature (CCT)
- CRI, CQS, TM-30, TLCI, RGB
- Circadian metrics, PAR
Accessories
Diffusors
In axis diffusors
Standard diffusor (ACC 013UV)
A standard diffusor is available to extend the measuring possibilities of specbos 1211-UV-2 to spectral Irradiance.
Additional Diffusor for specbos 1211UV and 1211UV-2 with filter OD0.5; OD1.0; OD1.5; OD2.0, others on request (ACC 013UV OD X.X)
8 mm Diffusor for specbos 1211UV and 1211UV-2 with short pass filter SP322, wavelength range 230 … 320 nm (ACC 020 SP)
8 mm Diffusor for specbos 1211UV and 1211UV-2 with UG11, wavelength range 250 … 400 nm (ACC 020 UG11)
Diffusor with 8 mm measuring diameter (ACC 026)
Diffusor with 8 mm diameter and 80° aperture (ACC 028)
Dome diffusor
The dome diffusor is equipped with a glass dom (silica for specbos 1211UV-2) and it is IP67 tested. It can be mounted on roofs or outdoor walls and allows a detection of the optical sky radiation. The standard length of the fiberoptic bundle is 3 m, so also longer distances between the measuring location and the indoor position of the measuring device can be spanned.
90° Diffusors
90° diffusor for specbos 1211UV and 1211UV-2 (ACC012UV)
90° diffusor for specbos 1211UV and 1211UV-2 with OD filter OD0.5; OD1.0; OD1.5; OD2.0 (ACC 012UV ODX.X)
Fiber extended diffusors
Length 35 cm/UV (ACC 015UV-035)
Length 1 m/UV (ACC 015UV-100)
Length 2 m/UV (ACC 015UV-200)
Length 3 m/UV (ACC 015UV-300)
Length 5 m/UV (ACC 015UV-500)
(other lengths on request)
Fiber extended 90° diffusor
Length 1 m/UV (ACC 019UV-100)
Length 3 m/UV (ACC 019UV-300)
(other lengths on request)
Fiber extended 90° diffusor with OD1.0 filter
Length 1 m/UV (ACC 019UV OD1-100)
(other lengths on request)
Fiber extended diffusor with dome
Length 3 m/UV (ACC 036-300UV)
(other lengths on request)
90° diffusor (ACC 012)
The standard diffusor of the device acts in line to the device. If the Illuminance at a low height above a surface needs to be measured, then the 90° diffusor can be applied. It is also available with attenuation filters to extend the Illuminance measuring range (ACC 012 ODx.x).
In axis remote diffusor (ACC 015-length)
If the measurement needs to be done in locations with limited space conditions then the remote diffusor can be used. It is a diffusor which is coupled to the spectraval device by an optical fiber bundle. The measurement is done in axis to the fiber bundle. Different fiber lengths are available.
90° remote diffusor, (ACC 019-length)
If the measurement needs to be done under limited space conditions and the in axis fiber coupled diffusor is not suited, then the 90° fiber coupled diffusor can be applied. Different fiber lengths are available.
Filters
Special imaging optics
Applications
Only specbos 1211-UV-2
Light effects
- Photobiological safety measurements
- Risk classification of flood lights
Miscellaneous
- Long term measurements of daylight and in green houses
- Metameric calculation
Technical notes
Devices
- TN03 Some detailed information about JETIs spectroradiometric equipment.pdf
- TN19 Comparison of monitor calibration with I1Pro, CS-200 and specbos 1211 L.pdf
- TN28 When I should select spectraval 15x1 instead of specbos 1211.pdf
- TN31 Comparison of JETI spectraval 15x1 with specbos 1211-2 and specbos 2501.pdf
Firm- and software
Communication
Downloads
Software JETI LiVal
SDK
Firmware
Additional information
External software
External software
Program | Manufacturer | Software | Driver | Firmware specbos 1211 | SDK (DLL) |
External Software packages | |||||
CalMAN | Portrait Displays | 5.9.0 | 2.12.28 | 1.71 | 4.4.0 |
LightSpace | LightIllusion | 7.1.7 | 2.12.28 | 1.70 | 4.4.0 |
ChromaPure | DisplayCalibrations | 3.0.8 | 2.12.28 | 1.71 | 4.4.0 |
Truelight | FilmLight | 4.0.6354 | 3.0.0 | ||
HCFR | open source | 3.2.0.0 | 2.08.30 | 3.0.0 | |
ArgyllCMS | open source | 1.9.1 | 3.0.0 | ||
ArgyllPro | open source | 1.1 | 3.0.2 | ||
Hardware related software | |||||
Monitor_AutoWhite Adjustment | Sony | 1.4.0.0 | 2.12.28 | 1.54 | 4.4.0 |
Monitor Calibration | JVC | 2.0.7 | 2.08.24 | 1.71 | |
CL-Soft | TVLogic | 1.6.2 T3 | 2.08.24 | 1.71 | 3.0.0 |
Calibrator | TVLogic | 1.7.1R1 | 3.2.3. | 4.0.18 | |
sonoVTSDisplayCenterQ | sonoVTS | 0.72 | 2.0 | 3.2.3 | |
ColorNavigator | EIZO | 6.4.17.101 | 3.2.6 | ||
Plura Calibration Suite 3G | Plura | 2.0 | 3.0.0 | ||
Monitor Calibrator | BON | 2.0.3 | 3.0.0 | 3.2.3 | |
Boland (CalMAN) | Portrait Displays | special worksheet | |||
IS-mini Manager | Fujifilm | 2.2.2 | 2.08.30 | 3.0.2 | 3.2.3 |